The right-half-plane zero

  • Explain physically why the boost and the buck-boost have a right-half-plane (RHP) zero.
  • Compute the RHP zero and the double-pole parameters of both converters from circuit values.
  • Know how the RHP zero limits the crossover frequency of a feedback loop.

In the boost, energy reaches the output only while the diode conducts, that is, during the off-interval. A step increase of the duty ratio lengthens the on-interval and shortens the off-interval. Eventually the inductor current rises and the output rises with it. Immediately after the step, however, the inductor current has not changed yet while the diode conducts for a shorter part of each period, so the average diode current, and the output voltage, first fall [Erickson & Maksimović 2020, Ch. 8]. The buck-boost behaves the same way.

A zero in the right half of the ss-plane produces exactly this: its magnitude rises with frequency like that of an ordinary zero, but its phase lags like that of a pole.

The boost’s control-to-output transfer function has a dc gain, a pair of poles and the RHP zero [Erickson & Maksimović 2020, Ch. 8]:

Gd0=Vg(1−D)2G_{d0} = \frac{V_g}{\left(1 - D\right)^{2}}
Gd0G_{d0}
dc control-to-output gain
DD
duty ratio
VgV_g
input voltage
Boost control-to-output dc gain, CCM✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Notes
equals ∂V/∂D\partial V/\partial D; with V=Vg/(1−D)V = V_g/(1 - D) this is also V/(1−D)V/(1 - D)
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
boost.ss.Gd0 · equations.yaml entry
ω0=1−DLC\omega_0 = \frac{1 - D}{\sqrt{L C}}
ω0\omega_0
LC corner frequency (rad/s)
CC
capacitance (output capacitor)
DD
duty ratio
LL
inductance
Boost: angular frequency of the LC poles✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
boost.ss.w0 · equations.yaml entry
Q=(1−D)RCLQ = \left(1 - D\right) R \sqrt{\frac{C}{L}}
QQ
quality factor
CC
capacitance (output capacitor)
DD
duty ratio
LL
inductance
RR
load resistance
Boost: quality factor of the LC poles✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
boost.ss.Q · equations.yaml entry
ωz=(1−D)2RL\omega_z = \frac{\left(1 - D\right)^{2} R}{L}
ωz\omega_z
RHP-zero frequency (rad/s)
DD
duty ratio
LL
inductance
RR
load resistance
Boost: right-half-plane zero✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Notes
moves down as the load gets heavier (smaller RR) and as DD increases
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
boost.ss.wz · equations.yaml entry

The poles belong to the inductor and the capacitor, but seen through the dc transformer of the averaged model the inductance appears divided by (1−D)2(1 - D)^2, which moves the poles down in frequency as DD grows.

Gd0=Vg(1−D)2G_{d0} = \frac{V_g}{\left(1 - D\right)^{2}}
Gd0G_{d0}
dc control-to-output gain
DD
duty ratio
VgV_g
input voltage
Buck-boost control-to-output dc gain (magnitude), CCM✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Notes
magnitude of ∂V/∂D\partial V/\partial D; the inverting output makes the gain itself negative
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
buckboost.ss.Gd0 · equations.yaml entry
ω0=1−DLC\omega_0 = \frac{1 - D}{\sqrt{L C}}
ω0\omega_0
LC corner frequency (rad/s)
CC
capacitance (output capacitor)
DD
duty ratio
LL
inductance
Buck-boost: angular frequency of the LC poles✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
buckboost.ss.w0 · equations.yaml entry
Q=(1−D)RCLQ = \left(1 - D\right) R \sqrt{\frac{C}{L}}
QQ
quality factor
CC
capacitance (output capacitor)
DD
duty ratio
LL
inductance
RR
load resistance
Buck-boost: quality factor of the LC poles✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
buckboost.ss.Q · equations.yaml entry
ωz=(1−D)2RDL\omega_z = \frac{\left(1 - D\right)^{2} R}{D L}
ωz\omega_z
RHP-zero frequency (rad/s)
DD
duty ratio
LL
inductance
RR
load resistance
Buck-boost: right-half-plane zero✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • ideal (lossless) switches and passive components
  • continuous conduction mode (CCM)
  • small-signal (linearised) model around a CCM operating point
  • resistive load R
Source
Erickson & Maksimović 2020, Ch. 8 (Converter Transfer Functions)
Derivation
step-by-step sympy derivation
Equation id
buckboost.ss.wz · equations.yaml entry

The derivations of all eight quantities from the averaged circuit are on the derivations page.

The RHP zero moves down in frequency as the load gets heavier (smaller RR) and as DD increases, so its lowest frequency occurs at full load and minimum input voltage. Because it adds phase lag while the magnitude keeps rising, the loop crossover frequency has to stay well below the lowest ωz\omega_z over the operating range [Erickson & Maksimović 2020, Ch. 8]. A compensator cannot cancel the zero: that would take a pole in the right half-plane, which is unstable.

The boost and buck-boost examples, both at the same duty ratio:

Boost example
SymbolValueHow it is obtained
VgV_g input voltage12 Vgiven
DD duty ratio0.5given
LL inductance100 µHgiven
CC capacitance (output capacitor)10 µFgiven
RR load resistance20 Ωgiven
Gd0G_{d0} dc control-to-output gain48 VBoost control-to-output dc gain, CCM
ω0\omega_0 LC corner frequency (rad/s)15.8 krad/sBoost: angular frequency of the LC poles
QQ quality factor3.16Boost: quality factor of the LC poles
ωz\omega_z RHP-zero frequency (rad/s)50 krad/sBoost: right-half-plane zero
Buck-boost example
SymbolValueHow it is obtained
VgV_g input voltage12 Vgiven
DD duty ratio0.5given
LL inductance100 µHgiven
CC capacitance (output capacitor)10 µFgiven
RR load resistance10 Ωgiven
Gd0G_{d0} dc control-to-output gain48 VBuck-boost control-to-output dc gain (magnitude), CCM
ω0\omega_0 LC corner frequency (rad/s)15.8 krad/sBuck-boost: angular frequency of the LC poles
QQ quality factor1.58Buck-boost: quality factor of the LC poles
ωz\omega_z RHP-zero frequency (rad/s)50 krad/sBuck-boost: right-half-plane zero

In the boost the RHP zero at 50 krad/s lies not far above the double pole at 15.8 krad/s: a loop that crossed over near the poles would already feel the zero’s phase lag.

▶ Open in the equation explorer: Boost: right-half-plane zero
Preset from the example boost-basic

Sweep RR downwards (heavier load): the zero falls in proportion to RR. Then set RR back and sweep DD instead.

On an open-loop boost at low power, apply a small step to the duty ratio, for example by stepping the modulator’s control input. Watch the output voltage with AC coupling, triggered on the step: it dips briefly before it rises to its new value. Repeat at a heavier load and compare the size of the dip.

  • Design for the worst case. The lowest RHP-zero frequency occurs at the heaviest load and the highest duty ratio, that is, the lowest input voltage.
  • The buck has no RHP zero. Its duty ratio acts on the switch node, which feeds the output filter directly; the boost and buck-boost deliver energy to the output only during the off-interval [Erickson & Maksimović 2020, Ch. 8].
  • Phase margin estimates must include the zero. Its phase lag starts well below ωz\omega_z, over the same frequencies where an ordinary zero’s phase lead would start.
  • Book chapter Converter Transfer Functions (Ch. 8) — R. W. Erickson, D. Maksimović · retrieved 2026-09-23
    Bode plots of the control-to-output transfer functions, including the right-half-plane zero of the boost and buck-boost.
  • Course Converter Control — University of Colorado Boulder (Coursera) · retrieved 2026-09-23
    Averaged small-signal models, converter transfer functions and feedback loop design.
  • Application note Understanding Boost Power Stages in Switchmode Power Supplies (SLVA061) — E. Rogers, Texas Instruments · retrieved 2026-09-23
    The boost counterpart: steady-state and small-signal analysis in CCM and DCM.
  1. Right after a step increase of the duty ratio, the output voltage of a boost converter briefly falls. Why?

    1. The inductor saturates
    2. The diode now conducts for a shorter part of each period while the inductor current has not risen yet
    3. The output capacitor discharges into the switch
    4. The control loop is unstable
    Answer and explanation

    Correct answer: B Energy reaches the output only while the diode conducts. A longer on-interval shortens the diode interval at once, but the inductor current needs time to grow, so the average diode current first drops.

  2. How does a right-half-plane zero affect a Bode plot?

    1. Its magnitude falls like a pole and its phase leads like a zero
    2. Its magnitude rises like a zero but its phase lags like a pole
    3. It changes only the magnitude
    4. It changes only the phase
    Answer and explanation

    Correct answer: B The magnitude of 1−s/ωz1 - s/\omega_z grows with frequency exactly like that of 1+s/ωz1 + s/\omega_z, but its phase goes towards −90∘-90^\circ instead of +90∘+90^\circ.

  3. A boost converter runs at D=0.5D = 0.5 with R=10 ΩR = 10\,\Omega and L=100 μHL = 100\,\mu\mathrm{H}. Where is its RHP zero?

    1. 12.5 krad/s12.5\,\mathrm{krad/s}
    2. 25 krad/s25\,\mathrm{krad/s}
    3. 50 krad/s50\,\mathrm{krad/s}
    4. 100 krad/s100\,\mathrm{krad/s}
    Answer and explanation

    Correct answer: B The zero is at (1−D)2R/L(1 - D)^2 R/L: a quarter of 10 Ω10\,\Omega divided by 100 μH100\,\mu\mathrm{H}.

  4. Under which conditions is the RHP zero of a boost converter at its lowest frequency?

    1. Light load and low duty ratio
    2. Heavy load and high duty ratio
    3. Light load and high duty ratio
    4. It does not depend on the operating point
    Answer and explanation

    Correct answer: B The zero is proportional to (1−D)2R(1 - D)^2 R: a small load resistance (heavy load) and a large duty ratio (low input voltage) both move it down.

  5. Why can the RHP zero not be cancelled by the compensator?

    1. Cancelling it would need a pole in the right half-plane, which is unstable
    2. Compensators cannot contain poles
    3. The zero is above the switching frequency
    4. It can be cancelled with a left-half-plane zero
    Answer and explanation

    Correct answer: A Cancellation places a pole at the same location as the zero. For a right-half-plane zero that pole would be unstable, so the crossover frequency has to stay well below the zero instead.

  6. With the same LL and CC, how does the double-pole frequency of a CCM boost at D=0.5D = 0.5 compare with that of a buck?

    1. It is the same
    2. It is twice as high
    3. It is half as high
    4. It is four times lower
    Answer and explanation

    Correct answer: C For the boost ω0\omega_0 is (1−D)/LC(1 - D)/\sqrt{LC}, the buck value times 1−D1 - D, because the inductance appears as L/(1−D)2L/(1 - D)^2 in the averaged model.

The numbers in the examples, presets and exercises on this site are synthetic: round teaching values, not data from any real design.