Leakage inductance
Intent
Section titled “Intent”- Explain leakage inductance as the flux that links one winding but not the other, stored mostly between the windings.
- Relate the coupling coefficient, the short-circuit inductance and the leakage inductances of the transformer model.
- Estimate the leakage of a winding arrangement, and what it costs in a flyback.
Theory
Section titled “Theory”Coupled windings
Section titled “Coupled windings”Two windings on one core share most of their flux, but not all of it. At their terminals they behave as two self-inductances, and , and a mutual inductance [Erickson & Maksimović 2020, Ch. 10], [Alexander & Sadiku 2017, Ch. 13]. How much of the flux they share is the coupling coefficient:
- coupling coefficient
- inductance of winding 1, winding 2 open
- mutual inductance
- inductance of winding 2, winding 1 open
Assumptions, convention and source
- Assumptions
- definition
- Notes
- 1 for perfect coupling; the leakage inductances make it smaller
- Source
- Erickson & Maksimović 2020, Ch. 10 (Basic Magnetics Theory: the transformer model; coupled inductors); Alexander & Sadiku 2017, Ch. 13 (Magnetically Coupled Circuits)
- Equation id
xfmr.k· equations.yaml entry
The short-circuit test
Section titled “The short-circuit test”Shorting the secondary holds its voltage, the rate of change of its flux linkage, at zero: its current then cancels most of the flux the two windings share, and the primary sees mainly the two windings’ leakage (derived here):
- inductance with the other winding shorted
- inductance of winding 1, winding 2 open
- coupling coefficient
Assumptions, convention and source
- Assumptions
- two linearly coupled windings without resistance
- Notes
- the short holds the second winding's voltage, the rate of change of its flux linkage, at zero, so its current cancels most of the flux the two windings share; what is left is mainly the two windings' leakage (`xfmr.L_sc_T`): 1 − k² is small for a well-coupled transformer
- Source
- Erickson & Maksimović 2020, Ch. 10 (Basic Magnetics Theory: the transformer model; coupled inductors); derived here; Alexander & Sadiku 2017, Ch. 13 (Magnetically Coupled Circuits)
- Derivation
- step-by-step sympy derivation
- Equation id
xfmr.L_sc· equations.yaml entry
With close to 1 this is a small fraction of : an impedance meter at the primary, with the secondary shorted, measures it directly.
The transformer model
Section titled “The transformer model”The transformer model splits each winding’s inductance into a leakage inductance and the magnetizing inductance the two share, with an ideal 1: transformer between them [Erickson & Maksimović 2020, Ch. 10]. Seen from the primary with the secondary shorted:
- inductance with the other winding shorted
- magnetizing inductance (primary)
- primary leakage inductance
- secondary leakage inductance, referred to the primary
Assumptions, convention and source
- Assumptions
- two linearly coupled windings without resistance
- transformer modelled by its magnetizing inductance and one leakage inductance per winding (T model), referred to the primary
- Notes
- with much larger than the leakage inductances, : the short-circuit test measures the total leakage referred to the primary, not how it divides between the windings
- Source
- Erickson & Maksimović 2020, Ch. 10 (Basic Magnetics Theory: the transformer model with magnetizing and leakage inductances); derived here
- Derivation
- step-by-step sympy derivation
- Equation id
xfmr.L_sc_T· equations.yaml entry
Since is much larger than the leakage inductances, the short-circuit test measures the sum of the two leakage inductances referred to the primary, the leakage that a flyback’s clamp has to absorb. It does not tell how that sum divides between the windings.
Where the leakage flux lives
Section titled “Where the leakage flux lives”The leakage flux runs through the winding window. Its energy follows from the magnetomotive force across the window: it rises through the primary’s layers, stays at its peak across the spacing, and falls back to zero through the secondary (leakage, P-S) [Erickson & Maksimović 2020, Ch. 10]. Splitting the primary around the secondary halves the peak and brings the leakage down to about a quarter (leakage, P-S-P). Only the winding geometry and the permeability of free space enter these equations: the core material and the gap set the magnetizing inductance, not the leakage.
What leakage costs
Section titled “What leakage costs”When a flyback’s switch turns off, the energy stored in the leakage inductance (leakage energy) cannot reach the secondary. It goes to a clamp or a snubber in every period (leakage power) [Erickson & Maksimović 2020, Ch. 4]; see snubbers and clamps.
Worked example
Section titled “Worked example”An example pair of windings, as an impedance meter reads them:
| Symbol | Value | How it is obtained |
|---|---|---|
| inductance of winding 1, winding 2 open | 404 µH | given |
| inductance of winding 2, winding 1 open | 25.3 µH | given |
| mutual inductance | 100 µH | given |
| magnetizing inductance (primary) | 400 µH | given |
| primary leakage inductance | 4 µH | given |
| secondary leakage inductance, referred to the primary | 4 µH | given |
| turns ratio, secondary/primary | 0.25 | given |
| coupling coefficient | 0.99 | Coupling coefficient of two windings |
| inductance with the other winding shorted | 7.96 µH | Inductance of a winding with the other winding shorted |
| inductance with the other winding shorted | 7.96 µH | Short-circuit inductance in the transformer model |
| open-circuit voltage ratio | 0.248 | Open-circuit voltage ratio of a transformer |
The coupling coefficient is 0.9901. With the secondary shorted, the primary reads 7.96 µH. The transformer model with 400 µH magnetizing inductance and 4 µH and 4 µH of leakage at the primary and the secondary, both referred to the primary, gives the same value, 7.96 µH: nearly the sum of the two. With the secondary open, the voltage ratio is 0.2475, just below the turns ratio of 0.25 (see measuring magnetics).
Try it
Section titled “Try it”▶ Open in the equation explorer: Inductance of a winding with the other winding shorted
Preset from the example coupled-pair
Sweep from 0.9 towards 1: the short-circuit inductance falls with . A small change in near 1 changes the leakage a lot.
Bench exercise
Section titled “Bench exercise”Measure a transformer’s primary inductance with the secondary open, then with it shorted by a short, wide link, with an LCR meter reading the series inductance. Choose a test frequency well below the self-resonance and high enough that the shorted reading no longer changes with frequency (see Measuring magnetics). The ratio of the two readings gives through the short-circuit equation. Then connect the two windings in series, aiding and opposing: the difference of the two readings is four times the mutual inductance [Alexander & Sadiku 2017, Ch. 13]. Compare the measured leakage with the estimate from the winding geometry.
Gotchas
Section titled “Gotchas”- The short adds its own inductance. A long or thin shorting wire adds to the reading; use a short, wide link.
- Too low a test frequency reads high. With the secondary shorted, the magnetizing inductance’s reactance must be much larger than the secondary’s resistance referred to the primary; otherwise it carries part of the current and the reading rises towards the open-circuit inductance.
- The test gives the sum. The short-circuit test measures the primary’s and the secondary’s leakage together, referred to the primary.
- A gap does not remove leakage. Gapping the core lowers and , but the leakage inductance itself is set by the windings.
Go deeper
Section titled “Go deeper”- Book chapter Basic Magnetics Theory (Ch. 10)
Magnetic circuits, the transformer model with magnetizing and leakage inductance, and core and winding loss mechanisms. - Book chapter Transformer Design (Ch. 12)
Designing a transformer when core loss, rather than saturation, limits the ac flux density, with copper and core loss traded against each other. - Book Magnetics Design Handbook (SLUP132)
Lloyd Dixon's magnetics design handbook, reproduced by TI from the 2001 Unitrode edition. The ti.com copy requires a free myTI login.
Two windings read and , each with the other open, and their mutual inductance is . What is their coupling coefficient?
Answer and explanation
Correct answer: B The mutual inductance over the square root of the product of the two inductances: 99 over 100.
A primary reads with the secondary open, and the coupling coefficient is 0.99. What does it read with the secondary shorted?
Answer and explanation
Correct answer: B The open-circuit inductance times one minus the coupling coefficient squared: 1 mH times 0.0199.
What does the short-circuit test measure?
Answer and explanation
Correct answer: A With the magnetizing inductance much larger than the leakage, the reading is nearly the sum of the two leakage inductances referred to the primary.
Splitting the primary around the secondary (P-S-P) changes the leakage roughly how?
Answer and explanation
Correct answer: C The peak MMF in the window halves, and the stored energy goes with its square.
A core's gap is made twice as long. What happens to the leakage inductance?
Answer and explanation
Correct answer: B The gap lowers the magnetizing inductance; the leakage is set by the field between the windings, which the gap hardly touches.
Where does a flyback's leakage energy go when the switch turns off?
Answer and explanation
Correct answer: C The leakage flux does not link the secondary, so its energy cannot reach the output; a clamp or snubber must take it.
The numbers in the examples, presets and exercises on this site are synthetic: round teaching values, not data from any real design.