Leakage inductance

  • Explain leakage inductance as the flux that links one winding but not the other, stored mostly between the windings.
  • Relate the coupling coefficient, the short-circuit inductance and the leakage inductances of the transformer model.
  • Estimate the leakage of a winding arrangement, and what it costs in a flyback.

Two windings on one core share most of their flux, but not all of it. At their terminals they behave as two self-inductances, L11L_{11} and L22L_{22}, and a mutual inductance L12L_{12} [Erickson & Maksimović 2020, Ch. 10], [Alexander & Sadiku 2017, Ch. 13]. How much of the flux they share is the coupling coefficient:

k=L12L11L22k = \frac{L_{12}}{\sqrt{L_{11} L_{22}}}
kk
coupling coefficient
L11L_{11}
inductance of winding 1, winding 2 open
L12L_{12}
mutual inductance
L22L_{22}
inductance of winding 2, winding 1 open
Coupling coefficient of two windings✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • definition
Notes
1 for perfect coupling; the leakage inductances make it smaller
Source
Erickson & Maksimović 2020, Ch. 10 (Basic Magnetics Theory: the transformer model; coupled inductors); Alexander & Sadiku 2017, Ch. 13 (Magnetically Coupled Circuits)
Equation id
xfmr.k · equations.yaml entry

Shorting the secondary holds its voltage, the rate of change of its flux linkage, at zero: its current then cancels most of the flux the two windings share, and the primary sees mainly the two windings’ leakage (derived here):

Lsc=L11(1−k2)L_\mathrm{sc} = L_{11} \left(1 - k^{2}\right)
LscL_\mathrm{sc}
inductance with the other winding shorted
L11L_{11}
inductance of winding 1, winding 2 open
kk
coupling coefficient
Inductance of a winding with the other winding shorted✓ verified by 8 tests
Assumptions, convention and source
Assumptions
  • two linearly coupled windings without resistance
Notes
the short holds the second winding's voltage, the rate of change of its flux linkage, at zero, so its current cancels most of the flux the two windings share; what is left is mainly the two windings' leakage (`xfmr.L_sc_T`): 1 − k² is small for a well-coupled transformer
Source
Erickson & Maksimović 2020, Ch. 10 (Basic Magnetics Theory: the transformer model; coupled inductors); derived here; Alexander & Sadiku 2017, Ch. 13 (Magnetically Coupled Circuits)
Derivation
step-by-step sympy derivation
Equation id
xfmr.L_sc · equations.yaml entry

With kk close to 1 this is a small fraction of L11L_{11}: an impedance meter at the primary, with the secondary shorted, measures it directly.

The transformer model splits each winding’s inductance into a leakage inductance and the magnetizing inductance LML_M the two share, with an ideal 1:nn transformer between them [Erickson & Maksimović 2020, Ch. 10]. Seen from the primary with the secondary shorted:

Lsc=Lℓ1+Lℓ2′LMLℓ2′+LML_\mathrm{sc} = L_{\ell 1} + \frac{L_{\ell 2}' L_M}{L_{\ell 2}' + L_M}
LscL_\mathrm{sc}
inductance with the other winding shorted
LML_M
magnetizing inductance (primary)
Lℓ1L_{\ell 1}
primary leakage inductance
Lℓ2′L_{\ell 2}'
secondary leakage inductance, referred to the primary
Short-circuit inductance in the transformer model✓ verified by 7 tests
Assumptions, convention and source
Assumptions
  • two linearly coupled windings without resistance
  • transformer modelled by its magnetizing inductance and one leakage inductance per winding (T model), referred to the primary
Notes
with LML_M much larger than the leakage inductances, Lsc≈Lℓ1+Lℓ2′L_\mathrm{sc} \approx L_{\ell 1} + L_{\ell 2}': the short-circuit test measures the total leakage referred to the primary, not how it divides between the windings
Source
Erickson & Maksimović 2020, Ch. 10 (Basic Magnetics Theory: the transformer model with magnetizing and leakage inductances); derived here
Derivation
step-by-step sympy derivation
Equation id
xfmr.L_sc_T · equations.yaml entry

Since LML_M is much larger than the leakage inductances, the short-circuit test measures the sum of the two leakage inductances referred to the primary, the leakage LlkL_\mathrm{lk} that a flyback’s clamp has to absorb. It does not tell how that sum divides between the windings.

The leakage flux runs through the winding window. Its energy follows from the magnetomotive force across the window: it rises through the primary’s layers, stays at its peak across the spacing, and falls back to zero through the secondary (leakage, P-S) [Erickson & Maksimović 2020, Ch. 10]. Splitting the primary around the secondary halves the peak and brings the leakage down to about a quarter (leakage, P-S-P). Only the winding geometry and the permeability of free space enter these equations: the core material and the gap set the magnetizing inductance, not the leakage.

When a flyback’s switch turns off, the energy stored in the leakage inductance (leakage energy) cannot reach the secondary. It goes to a clamp or a snubber in every period (leakage power) [Erickson & Maksimović 2020, Ch. 4]; see snubbers and clamps.

An example pair of windings, as an impedance meter reads them:

Coupled windings example
SymbolValueHow it is obtained
L11L_{11} inductance of winding 1, winding 2 open404 µHgiven
L22L_{22} inductance of winding 2, winding 1 open25.3 µHgiven
L12L_{12} mutual inductance100 µHgiven
LML_M magnetizing inductance (primary)400 µHgiven
Lℓ1L_{\ell 1} primary leakage inductance4 µHgiven
Lℓ2′L_{\ell 2}' secondary leakage inductance, referred to the primary4 µHgiven
nn turns ratio, secondary/primary0.25given
kk coupling coefficient0.99Coupling coefficient of two windings
LscL_\mathrm{sc} inductance with the other winding shorted7.96 µHInductance of a winding with the other winding shorted
LscT{L_\mathrm{sc}}_{\mathrm{T}} inductance with the other winding shorted7.96 µHShort-circuit inductance in the transformer model
V2/V1V_2/V_1 open-circuit voltage ratio0.248Open-circuit voltage ratio of a transformer

The coupling coefficient is 0.9901. With the secondary shorted, the primary reads 7.96 µH. The transformer model with 400 µH magnetizing inductance and 4 µH and 4 µH of leakage at the primary and the secondary, both referred to the primary, gives the same value, 7.96 µH: nearly the sum of the two. With the secondary open, the voltage ratio is 0.2475, just below the turns ratio of 0.25 (see measuring magnetics).

▶ Open in the equation explorer: Inductance of a winding with the other winding shorted
Preset from the example coupled-pair

Sweep kk from 0.9 towards 1: the short-circuit inductance falls with 1−k21 - k^2. A small change in kk near 1 changes the leakage a lot.

Measure a transformer’s primary inductance with the secondary open, then with it shorted by a short, wide link, with an LCR meter reading the series inductance. Choose a test frequency well below the self-resonance and high enough that the shorted reading no longer changes with frequency (see Measuring magnetics). The ratio of the two readings gives kk through the short-circuit equation. Then connect the two windings in series, aiding and opposing: the difference of the two readings is four times the mutual inductance [Alexander & Sadiku 2017, Ch. 13]. Compare the measured leakage with the estimate from the winding geometry.

  • The short adds its own inductance. A long or thin shorting wire adds to the reading; use a short, wide link.
  • Too low a test frequency reads high. With the secondary shorted, the magnetizing inductance’s reactance must be much larger than the secondary’s resistance referred to the primary; otherwise it carries part of the current and the reading rises towards the open-circuit inductance.
  • The test gives the sum. The short-circuit test measures the primary’s and the secondary’s leakage together, referred to the primary.
  • A gap does not remove leakage. Gapping the core lowers LML_M and kk, but the leakage inductance itself is set by the windings.
  • Book chapter Basic Magnetics Theory (Ch. 10) — R. W. Erickson, D. Maksimović · retrieved 2026-09-23
    Magnetic circuits, the transformer model with magnetizing and leakage inductance, and core and winding loss mechanisms.
  • Book chapter Transformer Design (Ch. 12) — R. W. Erickson, D. Maksimović · retrieved 2026-09-24
    Designing a transformer when core loss, rather than saturation, limits the ac flux density, with copper and core loss traded against each other.
  • Book Magnetics Design Handbook (SLUP132) — L. H. Dixon, Texas Instruments (Unitrode) · retrieved 2026-09-23
    Lloyd Dixon's magnetics design handbook, reproduced by TI from the 2001 Unitrode edition. The ti.com copy requires a free myTI login.
  1. Two windings read 400 μH400\,\mu\mathrm{H} and 25 μH25\,\mu\mathrm{H}, each with the other open, and their mutual inductance is 99 μH99\,\mu\mathrm{H}. What is their coupling coefficient?

    1. 0.25
    2. 0.99
    3. 4
    4. 0.0099
    Answer and explanation

    Correct answer: B The mutual inductance over the square root of the product of the two inductances: 99 over 100.

  2. A primary reads 1 mH1\,\mathrm{mH} with the secondary open, and the coupling coefficient is 0.99. What does it read with the secondary shorted?

    1. 10 μH10\,\mu\mathrm{H}
    2. 19.9 μH19.9\,\mu\mathrm{H}
    3. 990 μH990\,\mu\mathrm{H}
    4. 1.99 μH1.99\,\mu\mathrm{H}
    Answer and explanation

    Correct answer: B The open-circuit inductance times one minus the coupling coefficient squared: 1 mH times 0.0199.

  3. What does the short-circuit test measure?

    1. The primary's and the secondary's leakage together, referred to the primary
    2. The magnetizing inductance
    3. The primary's leakage alone
    4. The winding capacitance
    Answer and explanation

    Correct answer: A With the magnetizing inductance much larger than the leakage, the reading is nearly the sum of the two leakage inductances referred to the primary.

  4. Splitting the primary around the secondary (P-S-P) changes the leakage roughly how?

    1. To about half
    2. It doubles
    3. To about a quarter
    4. Not at all
    Answer and explanation

    Correct answer: C The peak MMF in the window halves, and the stored energy goes with its square.

  5. A core's gap is made twice as long. What happens to the leakage inductance?

    1. It halves
    2. It barely changes: the winding geometry sets it
    3. It doubles
    4. It vanishes
    Answer and explanation

    Correct answer: B The gap lowers the magnetizing inductance; the leakage is set by the field between the windings, which the gap hardly touches.

  6. Where does a flyback's leakage energy go when the switch turns off?

    1. To the output
    2. Into the core, where it is lost as core loss
    3. To the clamp or snubber, every period
    4. It stays in the leakage inductance
    Answer and explanation

    Correct answer: C The leakage flux does not link the secondary, so its energy cannot reach the output; a clamp or snubber must take it.

The numbers in the examples, presets and exercises on this site are synthetic: round teaching values, not data from any real design.